Over Voltage Protection with TL431.
Voltage Protection 172VDC
When V1 exceeds 172V, LED1 (the led part of an optocoupler) is activated sending a signal that the programmed voltage has been exceeded.
V1 (threshold) = VR5 * (R5 + R6 + R653 + R652) / R5